Hv Gloves Testing
Helping you meet astm f496 requirements we offer accurate convenient testing services for new or in service electrical rubber gloves from class 00 to class 4 11 to 18 lengths and all cuff styles.
Hv gloves testing. They must also be visually inspected and gloves need to be air tested for any possible defects for example cuts holes tears embedded objects changes in texture before each day s use and whenever there is a reason to believe they may have been damaged. The gloves are issued to a qualified worker on february 1. Burlington safety laboratory is your source for linemen s protective equipment. If the gloves are not issued they will expire on december 31 and will require testing.
We have been serving electric utilities telecommunications companies railroads power line contractors and industrial accounts for more than 30 years. The air testing method is described in astm f496 14a standard specification for in service care of insulating gloves and sleeves. Protective ground grounding jumper testing and assembly an inspection at the high voltage test lab provides thorough mechanical visual and electrical testing for protective grounds grounding cables and bypass jumpers. All new gloves receive a fresh test date to insure maximum life until next test is required.
Basically the glove is filled with air either manually or with a power inflator and then checked for leakage. Complete inventory of new gloves to replace any that fail test so you can have the gloves you need right away. Osha also requires that insulating gloves be given an air test along with the inspection. What we offer for your high voltage grounding equipment test and clean all mechanical components.
Electrical glove testing egt magid s in house electrical glove testing egt lab is one of the most sophisticated and automated in the industry. Astm f 496 also specifies air tests for the in service care of insulating gloves and sleeves. 29 cfr 1910 137 c 2 ii requires an air test be performed along with inspections for insulating gloves. You can depend on dival s expert technicians to provide the highest quality electrical glove inspections and testing services.
The gloves will expire and require testing on august 1. As testing begins the gloves are filled with water and the tester closes to safeguard our employees from electric shock potential. Voltage is applied for at least one minute for retest gloves and three minutes for new gloves. The glove is filled with air either manually or with a powered inflator and then checked for leakage.
Gloves and sleeves must be electrically tested before being issued for use. High voltage insulating rubber glove testing rubber insulating gloves are to be tested before first issue and every 6 months thereafter.