1 begingroup what kind of power and voltage can the cable in the photo possibly drive and why is it composed of a lot of small cables.
Hv cable cross section. What if the diameter of the single copper cables were a little bigger. Our standard high voltage cables which include 2xs f 2y 2xs fl 2y a2xs f 2y and a2xs fl 2y are designed for the primary distribution of power on networks with a voltage rating of 123kv. A maintain electrical safety and minimise adverse effects on the environment. Calculate cross section and conversion factors for cables and wires current carrying capacity.
High voltage power cables we provide high voltage power cables with a maximum cross sectional area of 2 500mm 2 and rated system voltages of up to 240kv. 33kv single core cables are available in the following cable conductor cross section areas. If aluminium rather than copper is used as the conductor material the additional cross sectional area required is more or less negligible in comparison. 70sqmm 95sqmm 120sqmm 150sqmm 185sqmm 240sqmm 300sqmm 400sqmm.
Viewed 8k times 3. 11 17 18 21 26 and 27. Figure 4 1 typical hv xlpe insulated power cables 4 2 hv underground cable system the major components of an underground hv cable system include. This means that they have a full rated insulation system which will consist of insulation semi con layers and a metallic shield.
High voltage cable cross section. Cross bonding grounding schemes are largely used on hv cable systems and they are very common above 72 5 kv voltage class while classic mv cable systems are usually solidly grounded and without interchanging the cables screens of the different phases i e. The cable metallic screen is directly connected to ground potential at both extremities in correspondence of cable terminations. Mv hv cables joints terminations connectors.
Secondary functions of transmission hv cables are to. 11kv 3 core cables are available in the following cable conductor cross section areas. And b provide a whole of life cost effective service. In a low voltage lv plastic sheathed cable with conductor cross sections of up to 10 mm2 per conductor or in high voltage hv cables figure 2 the lion s share of the cross sectional area is occupied by the insulating material.
A high voltage cable hv cable is a cable used for electric power transmission at high voltage a cable includes a conductor and insulation cables are considered to be fully insulated. For medium voltage electrical data about 11kv 3 core cables including bending radius cable diameters cable drum lengths weight insulation type and cable sheath thicknesses please refer to the download opposite. 70sqmm 95sqmm 120sqmm 150sqmm 185sqmm 240sqmm 300sqmm 400sqmm 500sqmm 630sqmm 800sqmm 1000sqmm. Hv cable are triple extruded to the latest iec standards using proprietary materials on modern catenary line equipment.
Ask question asked 6 years 4 months ago. The cables are manufactured from high quality materials in state of the art facilities and they conform to both national and international quality and safety standards.